- Kiepe Việt Nam
- Festo Việt Nam
- Pavone Sistemi Việt Nam
- Met One Việt Nam
- Qualitest Việt Nam
- Intorq Việt Nam
- Omega Việt Nam
- Spohn & Burkhardt Việt Nam
- Pressure-tech Việt Nam
- Vega Việt Nam
- Fluoroline Việt Nam
- Okazaki Việt Nam
- Bircher Việt Nam
- Tempsens Việt Nam
- Burkert Việt Nam
- Orbinox Việt Nam
- Knick Việt Nam
- Minimax Việt Nam
- Gemu Việt Nam
- Kometer Việt Nam
- Cs Instruments Việt Nam
- Gunther Việt Nam
- Teclock Việt Nam
- Ashcroft Việt Nam
- Koganei Việt Nam
- DMN-Westinghouse
- Sinchold Việt Nam
- Sintrol Việt Nam
- ELAU SCHNEIDER VIỆT NAM
- DAIICHI ELECTRONICS VIỆT NAM
- DEUBLIN VIỆT NAM
- CELEM VIỆT NAM
- BAUMULLER VIỆT NAM
- BEIJER ELECTRONICS
- BROOKS IN STRUMENT
- Bircher Việt Nam
- AT2E Việt Nam
- Gastron Việt Nam
- Tek-trol Việt Nam
- Dwyer Việt Nam
- Okura Việt Nam
- Redlion Việt Nam
- TDK - Lambda Việt Nam
- Mark-10 Việt Nam
- Matsushima Việt Nam
- SCHENCKPROCESS
- CEMB
- FRIGORTEC
- D-hydro Việt Nam
- NETTER VIBRATION VIỆT NAM
- Tecfluid Việt Nam
Thết bị giám sát môi trường EXO / Sintrol Vietnam
Mã sản phẩm : Thiết bị giám sát môi trường EXO / Sintrol
Xuất xứ: USA
Email: sale11@tmpvietnam.com
Mô tả: Đại lý phân phối hãng SINTROL tại Việt Nam
Tình trạng: Mới 100%
Giá: Liên hệ
-
- Thông Tin Sản Phẩm
- Đánh Giá
EXO = EXtractive Optical PM monitor for CEMS
Extractive, isokinetic and temperature controlled continuous particulate measurement for wet processes.
- EXO system is designed to continuously measure the concentration of dust particles inside industrial stacks. It is an ideal solution for emission monitoring in wet conditions, for example after wet scrubbers or in condensing environments.
- EXO dust monitor consists of a heated sampling probe, optical XO sensor module, and an integrated panel PC, which are housed in a weather-proof powder-coated steel enclosure that is mounted on a frame. In a complete installation, the probe is inserted inside a stack perpendicular to the airflow using a flange. An external sample air blower supplies air to an ejector chamber at the end of the sampling line, creating a vacuum effect that draws flue gas through the internal piping of the device and ejects it back into the stack.
During operation, the probe continuously extracts a gas sample, which is heated to vaporize any moisture. The remaining particles are directed through the measurement chamber of the optical XO sensor module. Light from an LED is directed through the particle stream, which causes the light to scatter. A scattered light detector captures the scattered light and determines the particle concentration in the gas sample from the amount of scattered light. The underlying method is called “optical forward scattering”.
The device must be calibrated to the process conditions after installation using a standard reference method.
The user interface displays the measurement results as mg/m3 or 4-20 mA values.
* Features:
- Isokinetic sampling in variable flow conditions
- Continuous Dust levels as low as 0,1 mg/m³
- Sample stream isolated with air curtain to keep the optics clean -> long maintenance interval
- Accurate linear measurement for all kinds of dust
- Color touch screen for easy parametrization
- LED light source covers different particle size distributions and is less affected by particulate characteristic
LED based, forward scattering instrument to measure dust concentrations in difficult wet gases.
• Isokinetic sampling in variable flow conditions
• Continuous dust levels as low as 0,1 mg/m³
• Sample stream isolated with air curtain to keep the optics clean -> long maintenance interval
• Accurate linear measurement for all kinds of dust
• Color touch screen for easy parametrization
• LED light source covers different particle size distributions and is less affected by particulate characteristic
* Techinical Specifications:
Product Name |
EXO Optical Wet Gas Extractive Dust Monitor |
Measurement |
Total Dust, Optical LED Based, Extractive |
Particle Size |
From 0,01 µm |
Detection limit |
From 0.1 mg/m³ |
Measurement range |
0-500 mg/m³ (user changeable) |
Power supply |
400V/16A 3-Phase |
Power consumption |
Total: max 3.7 kW , heaters max 1,5 kW, blower max 2,2 kW |
Purge air supply |
Clean, dry instrument air ~30 l/min or separate purge air blower |
Output Signals |
2x8 digital output, 24 VDC , 0,5 A • Two 4-20 mA output • Ethernet TCP/IP • USB for datalogging |
Signal Averaging Time |
1 sec , 30 sec or user selectable (max 3600 sec) |
Ambient Temperature |
-20...+50°C |
Stack process conditions |
Flue gas below dew point with water droplets |
Ambient humidity |
Max 95 % RH (non-condensing) |
Flue Gas Velocity |
5-25 m/s |
Calibration |
SRM (standard reference method), gravimetric sampling |
Enclosure |
Powder coated steel, IP54 |
Size |
W: 800 mm, H: 400 mm, D: 300 mm |
Weight |
Total weight fully assembled ~120 kg, depending auxiliaries |
* CATALOG: