CẢM BIẾN ĐO BỤI S203

 

 

Trend monitor with 4-20 mA output for continuous dust measurement

 

Continuous trend monitor that gives plant operators to see the performance of the filtration systems and ducts over a period of time.  Perfect for installation after any filtration system or in common line channels leading into the emissions points of a plant.

State of the art Inductive Electrification principle minimizes the need for maintenance on the dust monitor and provides an accurate trend for end users.  4-20 mA output combined with an easy-to-use auto-setup feature that takes less than 30 minutes from installation makes the device both convenient and reliable. 

 

 

 

Features

  • Good value for money
  • Easy start-up and commissioning
  • Rugged design for harsh industrial conditions
  • Proven technology
  • Accurate dust measurement
  • Extremely wide measurement range
  • Normalized (instruments are all identical) instrument with a detection limit of 0.01 mg/m3

 

 

* Bảng vẽ:

 

    

 

* Thông số kỹ thuật:

 

      

Product Name

S201 PC901013 | S201 Ex PC901014 | S203 PC901012 | S203 Ex PC901024

 

Measurement objects

 

Total Suspended Particles (TSP)

Measurement range

Detection Limit 0.01 mg/m³ Maximum Range up to several g/m³, depending on conditions

 

Measurement principle

 

Inductive Electrification

 

Protection code

 

IP66

Power supply requirements

24 V DC ±10 %

100 ... 240 V AC ±10%, 50 / 60 Hz

 

Power consumption

 

Up to 10 W DC / AC

Output signals

2 × Independent SPDT dry contact relays, max. 30 V DC / 5 A or 240 V AC / 5 A, cos φ = 1

Isolated active 4 ... 20 mA output loop*, max. loop resistance 250 Ω

Communication interface

Serial communication RS-485

USB

Communication protocol

Modbus RTU (RS-485)

Sintrol network (USB, RF and RS-485)

Ambient Conditions

 

Temperature

−40 ... 60 °C (−40 ... 140 °F) / -30 ... 60 °C for Ex models

Humidity

Max. 95 % relative humidity (non-condensing)

Materials and Weight

 

 

Enclosure / casing

 

Aluminum

 

Weight

 

1.5 kg (3.3 lbs)

Process conditions

 

Temperature

Max. 300 °C (572 °F), optionally up to 700 °C (1292 °F)

Max. 250 °C (482 °F) with Teflon-coated probe

Max 200 °C for Ex models

Pressure

Max. 600 kPa (87.02 psi) in temperatures up  to 300 °C (572 °F)

Max. 300 kPa (43.51 psi) in temperatures from 300 °C (572 °F) to 700 °C (1292 °F) when high-temperature process connection is used

Hazardous location approvals Applicable to Ex models

IECEx/ATEX: II 2 D Ex ia/tb IIIC T200 93°C...201°C Da/Db -30°C < Ta < +60°C US: Zone 20 A Ex ia ta IIIC T85°C...T201°C Da CAN: Ex ia ta IIIC T85°C...T201°C Da US/CAN: CL II, DV 1, GP E, F, G. IS Probe Ta= -30°C to +60°C

 