- Kiepe Việt Nam
- Festo Việt Nam
- Pavone Sistemi Việt Nam
- Met One Việt Nam
- Qualitest Việt Nam
- Intorq Việt Nam
- Omega Việt Nam
- Spohn & Burkhardt Việt Nam
- Pressure-tech Việt Nam
- Vega Việt Nam
- Fluoroline Việt Nam
- Okazaki Việt Nam
- Bircher Việt Nam
- Tempsens Việt Nam
- Burkert Việt Nam
- Orbinox Việt Nam
- Knick Việt Nam
- Minimax Việt Nam
- Gemu Việt Nam
- Kometer Việt Nam
- Cs Instruments Việt Nam
- Gunther Việt Nam
- Teclock Việt Nam
- Ashcroft Việt Nam
- Koganei Việt Nam
- DMN-Westinghouse
- Sinchold Việt Nam
- Sintrol Việt Nam
- ELAU SCHNEIDER VIỆT NAM
- DAIICHI ELECTRONICS VIỆT NAM
- DEUBLIN VIỆT NAM
- CELEM VIỆT NAM
- BAUMULLER VIỆT NAM
- BEIJER ELECTRONICS
- BROOKS IN STRUMENT
- Bircher Việt Nam
- AT2E Việt Nam
- Gastron Việt Nam
- Tek-trol Việt Nam
- Dwyer Việt Nam
- Okura Việt Nam
- Redlion Việt Nam
- TDK - Lambda Việt Nam
- Mark-10 Việt Nam
- Matsushima Việt Nam
- SCHENCKPROCESS
- CEMB
- FRIGORTEC
- D-hydro Việt Nam
- NETTER VIBRATION VIỆT NAM
- Tecfluid Việt Nam
THIẾT BỊ THEO DÕI HẠT BỤI BAM 1020| MET ONE VIỆT NAM
Mã sản phẩm: THIẾT BỊ THEO DÕI HẠT BỤI BAM 1020 | MET ONE VIỆT NAM
Xuất xứ: USA
Email: sale11@tmpvietnam.com
Mô tả: Nhà cung cấp hãng MET ONE tại Việt Nam
Tình trạng: Mới 100%
Giá: Liên hệ
-
- Thông Tin Sản Phẩm
- Đánh Giá
THIẾT BỊ THEO DÕI HẠT BỤI BAM 1020| MET ONE VIỆT NAM
BAM 1020 tự động đo và ghi lại các mức nồng độ hạt trong không khí (tính bằng miligam hoặc microgam trên mét khối) bằng cách sử dụng nguyên tắc suy giảm tia beta đã được chứng minh trong ngành. Hàng nghìn thiết bị BAM 1020 hiện đang được triển khai trên toàn thế giới, khiến thiết bị này trở thành một trong những nền tảng giám sát không khí thành công nhất trên thế giới.
Đặt trưng
- U.S. EPA Equivalent Method for PM10, PM2.5, and PM10-2.5 monitoring
- Long term unattended remote operation of up to 60 days between site visits
- Very low operating costs
- Automatic Span Calibration checks
- Fast and easy field audits using common FRM audit tools
- Bench top or equipment rack mounting in mobile or stationary shelters
- Rugged anodized aluminum, stainless steel, and baked enamel construction
- Highly accurate, reliable, and mechanically simple flow system
- Hourly filter advances minimize effects on volatile compounds
- Advanced Smart Heater technology precisely controls sample relative humidity
- Integrated datalogger allows the connection of up to two multi-parameter meteorological sensors
- Data retrieval through RS-232 or RS-485 serial ports using direct PC connections, or digital data collection systems
Thông số kỹ thuật
Measurement Principle: Mass Concentration of Ambient Particulate Matter by Beta Attenuation
US-EPA Designations: US-EPA PM10 Equivalent Method: EQPM-0798-122
US-EPA Class III PM2.5 Equivalent Method: EQPM-0308-170
US-EPA PM10-2.5 Equivalent Method: EQPM-0709-185
Range: 0 - 10 mg/m3 (0 - 10,000 μg/m3)
Analog Ranges: 0 - 0.1, 0.2, 0.5, 1, 2, 5, 10 mg/m3 (others available)
Accuracy: Exceeds all US-EPA designation requirements for PM10, PM2.5, and PM10-2.5
Measurement Resolution: 0.1 μg/m3
Instrument noise (1 hour): Less than 2.4 μg/m3 (less than 2.0 μg/m3 typical). Auditable with zero filter test
Lower Detection Limit (2 ) (1 hour): Less than 4.8 μg/m3 (less than 4.0 μg/m3 typical). Auditable with zero filter test
Lower Detection Limit (2 ) (24 hours): Less than 1.0 μg/m3. Auditable with zero filter test
Measurement Cycle Time: 1 Hour (others available)
Flow Rate: 16.67 liters/minute. Actual flow
Filter Tape: Continuous glass fiber filter, 30mm x 21m roll. > 60 day operation/roll
Span Check: Manual; Automatic optional
Beta Source: 14C (carbon-14), 60 μCi ±15 μCi (< 2.22 X 106 Beq), Half-Life 5730 years
Beta Detector Type: Photomultiplier tube with plastic scintillator
Operating Temp. Range: 0° to +50°C
Operating Humidity Range: 0-90% non-condensing
Humidity Control: Actively controlled inlet heater module, 10% - 99% RH setpoint
Approvals: US-EPA, MCERTS, CE, NRC, TUV, CNEMC, Korea
User Interface: Graphic color touch screen display
Analog Output: 2 channels, voltage range 0-1 VDC, 0-2.5 VDC, 0-5 VDC
Serial Interface: RS-232 2-way serial ports for PC or modem communications, USB
Contact Closure Specification: 1 channel, dry, Normally Open contact 12 VDC 0.5 A
Alarm Contact Closures: Data Error, Tape Fault, Flow Error, Power Failure, Maintenance
Compatible Software: Air Plus™, COMET™, HyperTerminal®
Error Reporting: User-configurable. Available through serial port, display, and relay outputs
Memory: 14,000 records (1.6 years @ 1 record/hr)
Power Supply: 100 - 240 VAC, 50/60 Hz Universal input
Weight: 19 kg (42 lbs) without external accessories